Glucagon assay kit

Glucagon

产品货号:20-1010
产品规格:100/200/400 wells
产品备注:
该产品用于体外定量测定人血浆中的胰高血糖素。临床上主要用于糖尿病的辅助诊断。Product DescriptionGlucagon is a peptide consisting of 29 amino acids produced by the alpha cells of the islets ofLangerhans.Glucagon has been established as an important hormone that orchestrates glucose,lipid,and amino aci
產品描述

该产品用于体外定量测定人血浆中的胰高血糖素。临床上主要用于糖尿病的辅助诊断。


Product Description

Glucagon is a peptide consisting of 29 amino acids produced by the alpha cells of the islets of

Langerhans.Glucagon has been established as an important hormone that orchestrates glucose,lipid,and amino acid metabolism,as well as energy intake and expenditure.


Glucagon is a counter-regulatory hormone opposing the actions of insulin in glucose homoeostasis. Glucagon is thought to play an important role in the maintenance of fasting and postprandial glucose homeostasis.By stimulating hepatic glucose output, glucagon counterbalances the action of insulin and serves to maintain circulating glucose and prevent insulin mediated hypoglycemia.

 42.png



Both type 1 and type 2 diabetes frequently exhibit an inappropriately high glucagon response to a meal.The high levels of glucagon have been shown to contribute importantly to diabetic hyperglycemia and can result in ketoacidosis.Relative hyperglucagonemia, in the setting of deficient insulin secretion may contribute to the development of fasting and postprandial hyperglycemia in the patients.

 43.png


Measuring glucagon not so simple!

l  While glucagons actions may be unique, its sequence is not. Herein lies a major part of the measurement quandary that has faced scientists in years past.

l  Circulating levels of homologous proteins should also be taken into consideration and can make cross-reactivity in a glucagon assay particularly problematic, which is especially true for glicentin.

l  Inaccurate glucagon readings can have enormous negative implications on research and clinical decisions.

l  A true insulin:glucagon ratio cannot be determined if using assays (for either biomarker) that are not highly specific.

 

highly-specific glucagon assay

JinDes careful selection of glucagon antibody clones resulted in a true sandwich formation that would only be possible in the presence of glucagon, thus preventing cross-reactivity to related proteins that contain the full (e.g. glicentin) or partial (e.g. mini-glucagon) glucagon sequence.


Unstable plasma glucagon

The self-developed Antiglu® blood collection tube has been verified in clinical trials to enable

plasma glucagon samples to be stored stably for at least 4 days at 2~8 and 28 days at -20

 

37.png

 

Chemiluminescent Immunoassay

SPARCL (Spatial Proximity Analyte Reagent Capture Luminescence)

l  High sensitive

without solid support, no separation or wash step, sensitivities 2 pmol/L

l  Complete assays in less than 30 minutes

Save time with only one incubation step, instantaneous signal generation from flash

 23.png

 

Reference Range

2-18pmol/L

Analytic Measurement Range

2-128pmol/L

Specimen

Plasma

Shelf Life

12 months at 2-8℃